Accident: 14460315 - Employee'S Hand Lacerated In Plastic Shear

Accident: 14460315 -- Report ID: 0352420 -- Event Date: 03/29/1984
InspectionOpen DateSICEstablishment Name
1483983105/02/19843089Cindarn Plastic Inc
Employee #1's job was to put plastic holders into a box. The excess plastic traveled 7 in. on a conveyor to a cutting shear with a 30 in. long blade. After being cut, the plastic went through a metal slot into another box. The cutting shear was 52 1/2 in. above the floor. A clear plastic guard stood 13 in. above the shear and extended 40 in. from the blade to the operator. Employee #1 reached over or around the guard and suffered a cut requiring 19 stitches to close.
Keywords: shearing machine, shear, work rules, struck against, laceration, hand
Employee # Inspection Age Sex Degree Nature Occupation
1 14839831 Hospitalized injury Cut/Laceration Chemists, except biochemists

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.