Accident: 14443311 - Fall - Load Line Failed

Accident: 14443311 -- Report ID: 0355117 -- Event Date: 10/04/1984
InspectionOpen DateSICEstablishment Name
1521742510/12/19841541F B Bray Construction Co Inc
InspectionOpen DateSICEstablishment Name
1521743310/12/19841711Weather Conditioners Inc
InspectionOpen DateSICEstablishment Name
1521744110/12/19841742G & B Insulation Co Inc
InspectionOpen DateSICEstablishment Name
1521745810/12/19841731Williams Electric Co Inc
InspectionOpen DateSICEstablishment Name
1521741710/12/19841791Briley Construction Co
AN EMPLOYEE WAS WORKING AT ABOUT THE 200-FOOT LEVEL OF A STEEL COMMUNICATIONS TOWER UNDER CONSTRUCTION. A SECTION OF THE TOWER, 20 FEET BY 37 FEET, WEIGHING ABOUT 4000 POUNDS, WAS BEING HOISTED BY A WINCH TRUCK AND GIN POLE. THE SECTION HUNG UP ON THE TOWER FRAME. THE EMPLOYEE, WHO WAS NEARBY, CLIMBED ONTO THE STEEL SECTION IN AN ATTEMPT TO FREE IT. HE HAD HOOKED HIS SAFETY BELT LANYARD TO THE LOAD LINE OF THE HOISTING EQUIPMENT. BECAUSE OF THE PRESSURE BEING APPLIED BY THE THE WINCH TRUCK ON THE WIRE ROPE LOAD LINE, THE GIN POLE BENT AND SNAPPED. THIS CAUSED SLACK IN THE LINE. THE TOWER SECTION CAME LOOSE AND BOTH EMPLOYEE AND TOWER SECTION STARTED TO FALL. WHEN THE SLACK IN THE LINE WAS TAKEN UP, THE SUDDEN JERK BROKE THE LINE, CAUSING THE EMPLOYEE, WHO WAS TIED TO IT, TO FALL TO THE GROUND. THE TOWER SECTION HIT THE GROUND AND FELL OVER ONTO THE EMPLOYEE'S CHEST. THE EMPLOYEE DIED OF HIS INJURIES.
Keywords: lanyard, fall protection, tower, gin pole, derrick truck, fall, load line, telecom work, communication tower, construction
Employee # Inspection Age Sex Degree Nature Occupation
1 15217425 Occupation Not Listed
2 15217433 Occupation Not Listed
3 15217441 Occupation Not Listed
4 15217458 Occupation Not Listed
5 15217417 Fatality Other Structural metal workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close