Accident Report Detail
Accident: 14427009 - Employee Killed In Fall From Work Platform
Accident: 14427009 -- Report ID: 0830500 -- Event Date: 06/11/1986 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
100019082 | 06/12/1986 | 1541 | Townsend & Bottum | ||||
At approximately 11:55 a.m. on June 11, 1986, Employee #1, who was working on the construction of a power plant, entered a cyclone hopper to determine how a scaffold could be erected. He was walking on a platform when he fell approximately 40 ft, suffering a broken neck and severe chest injuries. Employee #1 was killed. A standard guardrail was not provided on the platform. | |||||||
Keywords:
chest, fracture, guardrail, work rules, construction, fall, fall protection, neck, elevated work plat
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 100019082 | Fatality | Fracture | Occupation not reported |