Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 14415855 - Employee Dies Of Suffocation In Cotton Seed Bin

Accident: 14415855 -- Report ID: 0729700 -- Event Date: 11/28/1995
InspectionOpen DateSICEstablishment Name
10659063111/29/19955153Cooperative Grain & Supply
A semi-truck was being unloaded when the bin-full alarm went off at the control station. The controller stated that when the alarm goes off there is usually about 3 ft remaining in the bin to be filled. Because the semi-truck still had cotton seed to be unloaded, the controller requested Employee #1 to go to the head house, verify how much more cotton seed the bin would take, and let him know, which he did via radio. After some time passed, coworkers realized that Employee #1 was missing. A search of the facility turned up nothing. A crew went to Employee #1's last known location and started searching again. After some time had passed, they decided to drain the bin. Employee #1 came out with the cotton seed. He had died of asphyxiation.
Keywords: asphyxiated, suffocated, caught by, flowing material, cotton, grain bin
Employee # Inspection Age Sex Degree Nature Occupation
1 106590631 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close