Accident Report Detail
Accident: 14385090 - Window Washer Fell 5 Floors After Rope Support Broke
Accident: 14385090 -- Report ID: 0524200 -- Event Date: 06/20/1985 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
2282721 | 06/21/1985 | 7349 | Aaa Services Inc | ||||
ON JUNE 20, 1985, EMPLOYEE #1 WAS WASHING WINDOWS FROM A BOSUN CHAIR USING A RAPPEL RACK DESCENDER ANCHORED TO THE ROOF OF A SIX STORY BUILDING. AT THE FIFTH FLOOR LEVEL, THE ROPE USED FOR HIS SUSPENSION LINE AND HIS SAFETY LIFELINE BROKE IN TWO PLACES. EMPLOYEE #1 FELL TO THE GROUND AND WAS PARALYZED FROM THE WAIST DOWN. A SERIOUS CITATION WAS ISSUED FOR THE USE OF A SCAFFOLD SUSPENSION ROPE NOT CAPABLE OF SUPPORTING AT LEAST SIX TIMES THE LOAD IT IS INTENDED TO SUPPORT -- 1910.28 (A) (22). | |||||||
Keywords:
window washer, paralysis, bosun chair, lifeline, scaffold collapse, fall, leg, scaffold
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 2282721 | Hospitalized injury | Fracture | Occupation not reported |