Accident: 14379820 - Eight Employees Exposed To Ethylene Oxide

Accident: 14379820 -- Report ID: 0522000 -- Event Date: 04/08/1987
InspectionOpen DateSICEstablishment Name
10165032304/10/19878062Grandview Hospital And Medical Center
ON APRIL 8,1987, SEVERAL EMPLOYEES WERE CLEANING, STERILIZING AND PACKING MEDICAL INSTRUMENTS AT THE CENTRAL PROCESSING AREA. ONE OF TWO GAS STERILIZATION UNITS, MODEL 2025, MANUFACTURED BY AMSCO, WAS BEING RUN BY EMPLOYEE #3. THE OTHER UNIT WAS NOT BEING USED. THE STERILIZER USES A GAS MIXTURE OF 12% ETHYLENE OXIDE AND 88% FREON. AT ABOUT 9 PM THAT DAY THE STERILIZER BECAME OVERPRESSURED AND RELEASED AN UNKNOWN QUANTITY OF STERILIZER GAS VIA A RELIEF VALVE. THE AREA WAS EVACUATED 5 TO 15 MINUTES LATER. INVESTIGATING EMPLOYEES #1,#5, AND #8, PLUS A MAINTENANCE EMPLOYEE DID NOT USE ANY RESPIRATORY PROTECTION DURING THEIR INVESTIGATION. EXPOSURE WAS CONFIRMED THROUGH THE USE OF A LEAK DETECTOR WHICH INDICATES THE PRESENCE OF ETO AT 10 PPM, AND DID PROVIDE SUCH INDICATION AT THE TIME OF THE LEAK. EIGHT EMPLOYEES WERE SENT TO THE EMERGENCY ROOM AND ADMITTED TO THE HOSPITAL OVERNIGHT FOR OBSERVATION. SOME TESTS WERE RUN. ALL EIGHT EMPLOYEES WERE RELEASED THE NEXT DAY. THEY SUFFERED NO HARMFUL EFFECTS FROM THE EXPOSURE.
Keywords: respiratory, ethylene oxide, inhalation, high pressure, chemical
Employee # Inspection Age Sex Degree Nature Occupation
1 101650323 Hospitalized injury Poisoning(Systemic) Occupation not reported
2 101650323 Hospitalized injury Poisoning(Systemic) Occupation not reported
3 101650323 Hospitalized injury Poisoning(Systemic) Occupation not reported
4 101650323 Hospitalized injury Poisoning(Systemic) Occupation not reported
5 101650323 Hospitalized injury Poisoning(Systemic) Occupation not reported
6 101650323 Hospitalized injury Poisoning(Systemic) Occupation not reported
7 101650323 Hospitalized injury Poisoning(Systemic) Occupation not reported
8 101650323 Hospitalized injury Poisoning(Systemic) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.