Accident: 14371850 - Employee Crushed And Killed By Industrial Robot

Accident: 14371850 -- Report ID: 0522000 -- Event Date: 05/17/1989
InspectionOpen DateSICEstablishment Name
10313296505/18/19893714Dayton-Walther Corporation/Moraine Div.
Employee #1 was working with an industrial robot that takes parts from a conveyor, feeds them into a machining operation; takes the parts and inserts them into a multi-spindle drill press; and then puts them on a spray painting turntable for rust-proofing. Employee #1 had apparently replaced a drill bit and returned to production but, because the parts didn't properly contact locator switches on the drill, the robot stopped. (This was a common problem.) Employee #1 apparently then reentered the robot area without locking out or hitting the "system stop" button or pushing the "hold" button. The "system stop" button can be hit earlier in the cycle before hitting "hold," and was found to override the "hold." Apparently Employee #1 pushed the parts against the locator switches that automatically activated the robot and the robot inadvertently crushed Employee #1 against the drill press. Employee #1 died. The original interlocked gate guards had been damaged over time, removed, and not replaced.
Keywords: robot, stop switch, inadequate maint, work rules, lockout, crushed, unguarded, machine--misc
Employee # Inspection Age Sex Degree Nature Occupation
1 103132965 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close