Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 14350532 - Employee Killed When Mixer He Was Cleaning Was Energized

Accident: 14350532 -- Report ID: 0418300 -- Event Date: 08/22/1984
InspectionOpen DateSICEstablishment Name
118605508/28/19843271Johnston Concrete Products Co Inc
EMPLOYEE #1 WAS CLEANING A CONCRETE BLOCK MIXING MACHINE FROM THE INSIDE. THE MACHINE WAS A BESSIR 50 CUBIC FOOT MIXER, POWERED BY A 40-HORSEPOWER AC 480-VOLT MOTOR. THE ACCIDENT OCCURRED WHEN EMPLOYEE #1 ENTERED THE MIXER WITHOUT DE-ENERGIZING IT AND LOCKING OUT THE POWER. WHILE HE WAS INSIDE, A FELLOW WORKER ENERGIZED THE MIXER WITHOUT REALIZING THAT EMPLOYEE #1 WAS INSIDE. EMPLOYEE #1'S FATAL INJURIES INCLUDED CUTS TO VARIOUS PARTS OF HIS BODY AND MULTIPLE AMPUTATIONS.
Keywords: amputated, cleaning, mixer, concrete mixer, lockout, laceration
Employee # Inspection Age Sex Degree Nature Occupation
1 1186055 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.