Accident: 14350383 - Fall From Open Sided Floor

Accident: 14350383 -- Report ID: 0418300 -- Event Date: 01/01/1985
InspectionOpen DateSICEstablishment Name
163458301/04/19851791Dover Elevator Co Inc
InspectionOpen DateSICEstablishment Name
163457501/04/19851791Cen Ten Steel Erectors Inc
InspectionOpen DateSICEstablishment Name
163866701/04/19851799Dee Shoring Co Inc
InspectionOpen DateSICEstablishment Name
198325301/04/19851542Harbert International Inc.
InspectionOpen DateSICEstablishment Name
198307101/04/19851542Mc Devitt & Street Co
InspectionOpen DateSICEstablishment Name
198324601/04/19851741Masonry Arts Co Inc
InspectionOpen DateSICEstablishment Name
198310501/04/19851791Southern Reinforcing
InspectionOpen DateSICEstablishment Name
198313901/07/19851731Electrican Inc
InspectionOpen DateSICEstablishment Name
198319601/07/19851629Harbert - Adhco /A Joint Venture
InspectionOpen DateSICEstablishment Name
198305501/07/19851791Regional Contracting Corp
InspectionOpen DateSICEstablishment Name
198322001/07/19851742Interior Specialty Construction
InspectionOpen DateSICEstablishment Name
198315401/04/19851761World Wide Metals
InspectionOpen DateSICEstablishment Name
198320401/04/19851799Galleria Concrete /A Joint Venture
InspectionOpen DateSICEstablishment Name
198306301/07/19851742Superior Drywall & Acoustical Inc.
InspectionOpen DateSICEstablishment Name
198321201/04/19851771Franklin Patterson Concrete Finishing
InspectionOpen DateSICEstablishment Name
198312101/04/19851711Hardy Corp
InspectionOpen DateSICEstablishment Name
198311301/07/19851711Air & Piping, Inc.
InspectionOpen DateSICEstablishment Name
198326101/07/19851741John Swindal Masonry Co Inc
InspectionOpen DateSICEstablishment Name
198314701/04/19851731Haymaker Electric Co Inc
InspectionOpen DateSICEstablishment Name
198316201/04/19851711Wallace Mechanical Corp
ON JANUARY 1, 1985, AT APPROXIMATELY 1:15 PM, EMPLOYEE #1 WAS STACKING 130 POUND "I" BEAM AT THE OPEN SIDED FLOORS EDGE OF THE 10TH FLOOR. THE GUARDRIAL HAD BEEN TAKEN DOWN SO THE EMPLOYEE COULD GET THE "I" BEAMS CLOSER TO THE FLOORS EDGE FOR LIFTING BY CRANE. WHILE THE EMPLOYEE WAS STACKING THIS "I" BEAM HE FELL OVER THE BUILDINGS EDGE TO HIS DEATH TEN FLOORS.
Keywords: building, fall, erection process, construction, steel erection
Employee # Inspection Age Sex Degree Nature Occupation
1 1634583 Occupation Not Listed
2 1634575 Occupation Not Listed
3 1638667 Fatality Concussion Occupation not reported
4 1983253 Occupation Not Listed
5 1983071 Occupation Not Listed
6 1983246 Occupation Not Listed
7 1983105 Occupation Not Listed
8 1983139 Occupation Not Listed
9 1983196 Occupation Not Listed
10 1983055 Occupation Not Listed
11 1983220 Occupation Not Listed
12 1983154 Occupation Not Listed
13 1983204 Occupation Not Listed
14 1983063 Occupation Not Listed
15 1983212 Occupation Not Listed
16 1983121 Occupation Not Listed
17 1983113 Occupation Not Listed
18 1983261 Occupation Not Listed
19 1983147 Occupation Not Listed
20 1983162 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close