Accident: 14348361 - Tank Ruptured And Spewed Hot Liquor On Employees

Accident: 14348361 -- Report ID: 0418400 -- Event Date: 02/04/1985
InspectionOpen DateSICEstablishment Name
196143202/07/19851742Howell Insulation Co., Inc.
InspectionOpen DateSICEstablishment Name
121929402/08/19851721John T. Friis Company
InspectionOpen DateSICEstablishment Name
121940102/08/19851791Mcabee Construction Inc.
InspectionOpen DateSICEstablishment Name
196144002/07/19851731Haines City Electric Inc.
InspectionOpen DateSICEstablishment Name
121940102/08/19851791Mcabee Construction Inc.
InspectionOpen DateSICEstablishment Name
121929402/08/19851721John T. Friis Company
InspectionOpen DateSICEstablishment Name
121938502/08/19851731Bailey Controls Company
InspectionOpen DateSICEstablishment Name
196144002/07/19851731Haines City Electric Inc.
InspectionOpen DateSICEstablishment Name
121930202/07/19851541Beloit Pulping Systems
InspectionOpen DateSICEstablishment Name
121929402/08/19851721John T. Friis Company
ON FEBRUARY 4, 1885, AT 9:30 AM, THE PRIME CONTRACTOR WAS RUNNING AN EXPERIMENT, BY COMPUTER, ON THE #10 DIGESTER. A SUBCONTRACTOR AND A PLANT EMPLOYEE WERE ASSISTING. A BLOW LINE PLUGGED. AIR AND STEAM FAILED TO CLEAR THE LINE. A SUBCONTRACTOR EMPLOYEE PULLED THE CARDS FROM THE BAILEY CONTROL NET 90 DISTRIBUTIVE CONTROL SYSTEM (COMPUTER). REMOVAL OF THE CARDS CAUSED THREE VALVES TO OPEN. THE OPENING OF TWO OF THESE VALVES CAUSED THE WARM LIQUOR ACCUMULATOR TANK TO OVERPRESSURIZE. THE TANK RUPTURED AT THE TOP WELDED SEAMS, BLOWING HOT BLACK LIQUOR ONTO EMPLOYEES #1 THROUGH #9, WHO WERE WORKING IN PROXIMITY TO THE TANK. THE CARDS SHOULD NOT HAVE BEEN PULLED AND THEN PLUGGED BACK IN WITHOUT SETTING THE DEFAULT VALVE FOR "CLOSED". CONTRACTOR PERSONNEL WORKING ON OR AROUND THE TANK SHOULD HAVE BEEN NOTIFIED OF THE EXPERIMENT AND INSTRUCTED TO TAKE THE REQUIRED ACTIONS TO PROTECT THEMSELVES.
Keywords: tank, burn, work rules, construction, rupture, high pressure
Employee # Inspection Age Sex Degree Nature Occupation
1 1961432 Non Hospitalized injury Burn(Chemical) Occupation not reported
2 1219294 Non Hospitalized injury Burn(Chemical) Occupation not reported
3 1219294 Hospitalized injury Other Occupation not reported
4 1219401 Fatality Burn(Chemical) Occupation not reported
5 1961440 Hospitalized injury Burn(Chemical) Occupation not reported
6 1219401 Hospitalized injury Burn(Chemical) Occupation not reported
7 1219294 Non Hospitalized injury Burn(Chemical) Occupation not reported
8 1219385 Occupation Not Listed
9 1961440 Non Hospitalized injury Burn(Chemical) Occupation not reported
10 1219302 Occupation Not Listed
11 1219294 Non Hospitalized injury Burn(Chemical) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.