Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 14348262 - Electric Shock - Accidentally Energized Electric Tool Frame

Accident: 14348262 -- Report ID: 0418400 -- Event Date: 10/30/1984
InspectionOpen DateSICEstablishment Name
122055710/31/19842451Fleetwood Homes Of Georgia Inc Westfield Div
IN THE MIDDLE OF THE MORNING, SOME EMPLOYEES DAMAGED AN EXTENSION CORD SET, APPARENTLY BY RUNNING OVER IT WITH A MOBILE HOME UNIT. INSTEAD OF TAKING THE CORD SET TO MAINTENANCE FOR REPAIR OR REPLACEMENT, ONE OF THE EMPLOYEES IN THE AREA ATTEMPTED TO REPAIR THE CORD. HIS REPAIR INTERCHANGED THE IDENTIFIED GROUNDED (WHITE) CONDUCTOR AND THE EQUIPMENT GROUNDING (GREEN) CONDUCTOR AT THE ATTACHMENT PLUG ON THE EXTENSION CORD SET. AT APPROXIMATELY 3 PM, EMPLOYEE #2 ATTEMPTED TO USE A 120-VOLT ELECTRIC ROUTER THAT WAS ENERGIZED THROUGH THIS EXTENSION CORD SET. THE CORD SET WAS PLUGGED INTO A PENDANT RECEPTACLE THAT HAD REVERSED POLARITY. THE FRAME OF THE ROUTER BECAME ENERGIZED, AND EMPLOYEE #2 FELT A TINGLE IN HIS HANDS AND DROPPED THE ROUTER TO THE FLOOR. ANOTHER EMPLOYEE WHO WAS WEARING SNEAKERS PICKED UP THE ROUTER AND HANDED IT TO EMPLOYEE #1. WHEN EMPLOYEE #1 LEANED AGAINST A GROUNDED METAL RAILING, HE WAS ELECTROCUTED.
Keywords: e gi v, electrical, reverse polarity, cord set, electrocuted, attachment plug, electric shock, elec port tool--misc
Employee # Inspection Age Sex Degree Nature Occupation
1 1220557 Fatality Electric Shock Occupation not reported
2 1220557 Non Hospitalized injury Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close