Accident: 14337133 - Employee Killed When Tire Explodes

Accident: 14337133 -- Report ID: 0419700 -- Event Date: 10/11/1987
InspectionOpen DateSICEstablishment Name
10034008210/21/19875541Dale'S Chevron
Employee #1 was inflating a customer's Firestone Steeltex LT 235185R16 tire when the tire ruptured, propelling him approximately 12 feet and causing him to strike his head against the concrete floor. Employee #1 was killed. A 6 1/2 inch split was observed in the sidewall of the tire after the explosion. The tire changer was a Bishman model 4400, with Chuck Knush rim hold-downs. Apparently the hold-downs failed, allowing the rim to strike Employee #1.
Keywords: head, struck against, equipment failure, explosion, restraining device, inflating, tire rim
Employee # Inspection Age Sex Degree Nature Occupation
1 100340082 Fatality Concussion Supervisors, mechanics and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.