Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 14314561 - Electric Shock - Contact With Overhead Line Thru Boom

Accident: 14314561 -- Report ID: 0317000 -- Event Date: 07/19/1989
InspectionOpen DateSICEstablishment Name
1771464307/20/19894911Philadelphia Electric Company
THE BOOM OF A TRUCK CRANE CONTACTED A 13-KILOVOLT OVERHEAD POWER LINE. AN ELECTRIC UTILITY EMPLOYEE WHO WAS TOUCHING THE CRANE WAS ELECTROCUTED WHEN THE CONTACT OCCURRED.
Keywords: overhead power line, electrical, boom, crane boom, truck crane, electrocuted, e ptd, elec utility work, crane
Employee # Inspection Age Sex Degree Nature Occupation
1 17714643 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close