Accident: 14312516 - Construction Employee Fell Into Asphalt Mixer; Crushed

Accident: 14312516 -- Report ID: 0213100 -- Event Date: 07/31/1987
InspectionOpen DateSICEstablishment Name
10064664507/31/19871611Gorman Bros Inc.
EMPLOYEE #1 WAS GREASING FITTINGS ON TOP OF THE PUG MILL BLACKTOP MIXER. HE FELL INTO THE MIXER PADDLES AND WAS FATALLY CRUSHED.
Keywords: mixer blade, maintenance, mixer, construction, lockout, crushed, fall, fall protection, asphalt
Employee # Inspection Age Sex Degree Nature Occupation
1 100646645 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.