Accident Report Detail

Accident: 14308258 - Fall - Collapsed Longspan Bar Joists

Accident: 14308258 -- Report ID: 0214200 -- Event Date: 09/21/1989
InspectionOpen DateSICEstablishment Name
10766001109/21/19891791Quality Steel Inc
InspectionOpen DateSICEstablishment Name
10765995509/21/19891791Sperber Crane Service Inc.
TWO EMPLOYEES WORKING AS CONNECTORS FELL 22' WITH FOUR BAR JOISTS AND BUNDLES OF BRIDGING AND SHEETING FROM ATOP A ONE STORY SKELETON STEEL 40,000 SQUARE FT STRUCTURE. THEY WERE PLACING AND SETTING 41'3'' INTER- MEDIATE LONG SPAN OPEN WEB STEEL BAR JOISTS ON THE ROOF BEAMS AT 22' LEVELS, USING A P&H 50 TON CAPACITY TRUCK CRANE (RENTAL MODEL "650ATC WITH A 120' LATTICE BOOM AND 40' JIB AND STANDING ON AN APPROX 22'6" L X36" W, 30 PIECE STACK OF METAL ROOF SHEETING WEIGHING APPROX 3,120 LBS ON TOP OF THE JOISTS. FOLLOWING THE JOIST FOREMAN'S DIRECTIONS TO REPOSITION TWO BUNDLES OF BRIDGING THAT WERE 1&1/2 X 1&1/2 X 90 DEG. ANGLE & APPROX 21'4" LONG CONTAINING 288 PIECES, WEIGHING APPROX 3,024 LBS. ALSO PRIOR LANDED. THEY CONNECTED TWO CHOKER SLINGS AND THE CRANE MOVED THE BUNDLE FROM ABOUT 1' AWAY FROM THE SUPPORT BEAM OUT ON THE 450 LB. JOIST TO ABOUT 8'. DISCONNECTED THE SLINGS, AND WITH THE HOOK ON THE WAY UP, FOUR BAR JOISTS, THE BUNDLES OFBRIDGING AND SHEETING WITH THE EMPLOYEES ON TOP FELL TO THE EARTH #1 EMPLOYEE LANDED ON THE JOIST, RUPTURED HIS HEART AND DIED, #2 EMPLOYEE FRACTURED HIS L/ANKLE. THE HEAVY EXTERNAL MATERIAL LOADS HAD BEEN PLACED ON TOP OF THE LONGSPAN JOISTS BEFORE THE JOISTS HAD BEEN TACK WELDED FOR SECURITY NOR HAD ANY BRIDGING BEEN INSTALLED FOR STABILITY, AS REQUIRED.
Keywords: joist, steel, building, collapse, steel erection, fall
Employee # Inspection Age Sex Degree Nature Occupation
1 107660011 Fatality Puncture Occupation not reported
2 107660011 Hospitalized injury Fracture Occupation not reported
3 107659955 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.