Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 14277115 - Fingers Amputated In A Mechanical Power Press

Accident: 14277115 -- Report ID: 0112300 -- Event Date: 07/26/1984
InspectionOpen DateSICEstablishment Name
181764208/08/19843873Faco Metal Products Inc
ON JUNE 27,1984 EMPLOYEE #1 WAS OPERATING A ROUSELLE, 10 TON CAPACITY, FULL REVOLUTION, MECHANICAL POWER PRESS, ASSEMBLING 2 5/8" PENDULUM PIECES. THE PRESS REPEATED, RESULTING IN EMPLOYEE #1 LOSING PORTIONS OF TWO FINGERS. INVESTIGATION REVEALED THAT A TENSION TYPE COIL SPRING, SUSPENDING THE CLUTCH ENGAGEMENT LEVER, BROKE, ALLOWING THE LEVER TO DROP. THIS CAUSED THE PRESS TO COMPLETE A CYCLE AS IF IN AUTOMATIC MODE. THE PRESS WAS EQUIPPED WITH A TWO HAND CONTROL SYSTEM. THE SYSTEM'S ARRANGEMENT, INSTALLATION AND OPERATION SEEMED TO BE ADEQUATE AND WHEN TESTED DID FUNCTION AS REQUIRED.
Keywords: amputated, clutch lever, power press, finger, two-hand control
Employee # Inspection Age Sex Degree Nature Occupation
1 1817642 Hospitalized injury Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.