Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 14259634 - Employee Killed By Toxic Fumes When Crawler Crane Overturns

Accident: 14259634 -- Report ID: 0625700 -- Event Date: 06/15/1984
InspectionOpen DateSICEstablishment Name
138653106/18/19841629International Maintenance Corp
Employee #1 was using a 225-ton American crane crawler crane, #9310, equipped with a 200-ft boom to hoist tube bundles to the top of a structure at an oil refinery. The weight of the load listed on the prints was in error; several weights, including the weight of headache ball on the whip line and the weight of the main hoist block, had not been deducted from the load rating chart when making the lifting plan. When the load was lifted with the main hoist block, the crane overturned, breaking lines in the pipe rack. Hydrogen sulfide gas blew into the cab of the crane, killing Employee #1.
Keywords: work rules, crawler crane, overloaded, construction, inhalation, gas leak, toxic fumes, accidental discharge, overturn
Employee # Inspection Age Sex Degree Nature Occupation
1 1386531 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close