Accident: 14254577 - Employee'S Fingers Amputated In Unguarded Punch Press

Accident: 14254577 -- Report ID: 0453710 -- Event Date: 06/30/1988
InspectionOpen DateSICEstablishment Name
1527304806/30/19883465Parker Industries, Inc.
Employee #1, the punch press operator, was reaching into the die for a defective/stuck part. when she inadvertently cycled the ram by the foot treadle. The point of operation was unguarded and Employee #1 amputated her left index, middle, and ring fingers at the second joint.
Keywords: maintenance, amputated, finger, work rules, foot control, point of operation, punch press, unguarded, inattention
Employee # Inspection Age Sex Degree Nature Occupation
1 15273048 Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.