Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 14238026 - Employee'S Face Burned By Flash Fire While Lighting Pilot

Accident: 14238026 -- Report ID: 0953210 -- Event Date: 05/04/1990
InspectionOpen DateSICEstablishment Name
11117413205/10/19907299Old Bridge Ranch
Employee #1 was attempting to relight the pilot lights on the grill portion of a Wolf propane range. He followed the procedures, but a gas pocket had formed in the pilot area. When Employee #1 reached into the range to light the pilots, a flash fire occurred. Employee #1 suffered first- and second-degree burns to his face. Apparently, the lack of a thermocoupler valve allowed the gas pocket to form.
Keywords: burn, pilot light, work rules, fire, cooker, gas, valve, propane, face
Employee # Inspection Age Sex Degree Nature Occupation
1 111174132 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.