Accident: 14236830 - Employee Injured In Fall From Platform

Accident: 14236830 -- Report ID: 0953210 -- Event Date: 06/16/1987
InspectionOpen DateSICEstablishment Name
10460883106/17/19871799J B Iron Inc
Employee #1 was installing a ladder up to a lighting platform in an auditorium. He climbed onto the lighting platform, removing the guardrail but not replacing it. He was starting to drill the concrete for an anchor lag placement when he lost his balance and fell 12 ft to the seating area. He was hospitalized. Employee #1 stated that he had been told by the field superintendent not to work on the platform without the guardrail in place.
Keywords: guardrail, installing, work rules, struck against, construction, fall, fall protection, elevated work plat, lost balance
Employee # Inspection Age Sex Degree Nature Occupation
1 104608831 Hospitalized injury Bruise/Contus/Abras Construction trades, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.