Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 14235386 - Employee Killed When Caught In Hydraulic Press

Accident: 14235386 -- Report ID: 0626300 -- Event Date: 05/31/1982
InspectionOpen DateSICEstablishment Name
144355506/04/19843443Tranter Inc Texas Division
Employee #1, a maintenance foreman, was adjusting the limit switch that controlled the ejector on a hydraulic press. He made several adjustments and then had the press operator cycle the press. Employee #1 felt that the adjustment was correct and asked the press foreman to have the operator run a trial part. When the press foreman returned to the rear of the press, he found that Employee #1 had crawled under the guide guard. Employee #1 was crushed and killed between the guide for the ejectors and the base of the press.
Keywords: maintenance, work rules, caught between, crushed, hydraulic press, press
Employee # Inspection Age Sex Degree Nature Occupation
1 1443555 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.