Accident: 14234801 - Electric Shock - Contact With Overhead Line Thru Load Line
Accident: 14234801 -- Report ID: 0627700 -- Event Date: 04/02/1991 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
107497125 | 04/02/1991 | 1389 | B & H Construction | ||||
AN OIL FIELD ROUSTABOUT CREW WAS MOVING AND ERECTING A THREE-TANK BATTERY EQUIPPED WITH A STAIRWAY AND A CATWALK. AN OPERATOR BACKED A GIN-POLE WINCH TRUCK INTO POSITION TO PERFORM THE LIFT. HE POSITIONED THE VEHICLE SO THAT THERE WAS ONLY ABOUT 8 INCHES OF CLEARANCE BETWEEN THE GIN POLES AND A 7200-VOLT OVERHEAD POWER LINE. AS ONE OF THE EMPLOYEES ATTACHED THE HOOK ON THE RIGGING LINE TO A STAIRWAY, THE UPPER PART OF THE WIRE ROPE CONTACTED THE POWER LINE. THE EMPLOYEE HOLDING THE RIGGING LINE WAS ELECTROCUTED. | |||||||
Keywords:
derrick truck, overhead power line, electrical, electrocuted, e gi ia, oil well servicing, load line
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 107497125 | Fatality | Electric Shock | Helpers, extractive occupations |