Accident Report Detail
Accident: 14223747 - Power Press Amputation
Accident: 14223747 -- Report ID: 0551800 -- Event Date: 02/13/1986 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
2721736 | 04/08/1986 | 3679 | Rca Consumer Electronics | ||||
At approximately 5:17 p.m. on February 13, 1986, Employee #1 stuck her hand through a 6-in.-wide by-5-in.-high opening of a part revolution Federal Power press #12, Serial Number 6A-544. Employee #1 was in the process of cleaning the resin build up off the die with a rag, when the press cycled, amputating the right thumb and index finger for which she was hospitalized. The press was in the company's in department 12 building #3, the opening was located 44.75 in. to 49.75 in. above the floors and 6.75 in. to 11.75 in. above press table, with the fixed barrier guard attached to the press. | |||||||
Keywords:
die, amputated, power press, finger, guard, cleaning
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 2721736 | Hospitalized injury | Amputation | Punching and stamping press machine operators |