Accident: 14219554 - One Employee Killed And Two Injured By Crane Hoist

Accident: 14219554 -- Report ID: 0626600 -- Event Date: 11/01/1990
InspectionOpen DateSICEstablishment Name
10762661611/01/19904491Ceres Gulf, Inc.
Employee #1, a 52-year-old longshoreman, was working aboard an ocean-going vessel, the Renate Schulte, at city dock #29, at the port of Houston, TX. He was off-loading containers from the aft end of the #2 hatch using a rented mobile shore crane, with an operator. The crane boom did not have any load on its hook when it fell across the ship. As the boom was falling, the crane's main hoist, four-part block, swung in the tween-deck, on the starboard side of the vessel, striking and killing Employee #1, and injuring Employees #2 and #3.
Keywords: longshoring, crane boom, work rules, mobile crane, hoist, ship, off loading, struck by, crane block, falling object
Employee # Inspection Age Sex Degree Nature Occupation
1 107626616 Hospitalized injury Bruise/Contus/Abras Occupation not reported
2 107626616 Fatality Bruise/Contus/Abras Occupation not reported
3 107626616 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.