Accident: 14216899 - Employee Dies Of Methylene Chloride Overexposure

Accident: 14216899 -- Report ID: 0150900 -- Event Date: 06/07/1990
InspectionOpen DateSICEstablishment Name
10379681906/08/19909223Stct Doc Northern Correctional Institution
On June 7, 1990, Employee #1 was removing paints and other finishes from furniture by dipping the furniture in a methylene chloride dip tank that measured 4 feet wide by 7 feet long by 42 inches high and contained 8 3/4 inches (approximately 160 gallons) of methylene chloride. There are two 11 inch working platforms located on both long sides of the tank. Two types of ventilation systems were in use at the dip tank: a push-pull type and a slotted-type. Both systems were operating at the time of the incident. Employee #1 was stripping the finish from church pews by pouring methylene chloride over the furniture with a 1 gallon can with an attached 51 inch handle. The furniture would then be scrubbed with a hard-bristled brush with a similar length handle. At approximately 9:00 a.m., Employee #1 complained to a coworker that he was not feeling well and that the methylene chloride was making him dizzy. Another worker saw Employee #1 bent over into the tank with one leg up on the side; he appeared to be retrieving something. Employee #1 was not seen between 9:30 and approximately 9:50 a.m. when a supervisor found him inside the methylene chloride dip tank. Attempts to revive him failed. Employee #1 was pronounced dead by a physician at the site. The medical examiner determined the cause of death to be acute methyl chloride toxicity from inhalation of high levels of methylene chloride. Causal factors included the following: 1) A standard guardrail was not provided to protect personnel from the hazards of the dip tank. 2) Subsequent air samples collected inside the dip tank, which simulated approximately the levels that Employee #1 could bend to, were in excess of both the OSHA ceiling limit and acceptable maximum peak limits for methylene chloride. 3) There was a lack of employee training for employees working in and around open surface tank operations. 4) Personnel protective equipment as required by applicable OSHA standards was not being worn. 5) The facility did not have an effective Hazard Communication Program.
Keywords: guardrail, ppe, methylene chloride, work rules, toxic atmosphere, inhalation, dip tank, toxic fumes, overexposure, untrained
Employee # Inspection Age Sex Degree Nature Occupation
1 103796819 Fatality Other Furniture and wood finishers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close