Accident Report Detail
Accident: 14201560 - Employee Suffers Flash Burns
Accident: 14201560 -- Report ID: 0352410 -- Event Date: 04/25/1989 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
108406737 | 05/26/1989 | 3499 | Keller Industries, Inc. | ||||
On April 25, 1989, four welders were standing side by side working in an assembly line arrangement spot-welding, tack-welding and finish- welding auto seat frames. The equipment used were four Airco Pulse-Arc 350 MIG wire arc-welding machines using .035 copper covered steel wire plus 25 percent CO2 & 75 percent argon gas. The operators were wearing welder's helmets, gloves, sleeves & beanies. The only lateral protection from the rays created by each individual welder operator were four Singer Trans-Vue orange 5-foot-6-in. wide by 5-foot-6-in. tall safety shields placed on the floor between welders, plus one 3-foot-square shield place welding table located in a straight line between the individual operators. No completely enclosed individual booth or screen was provided. Employee #1, a certified welder, suffered flash burns to both eyes generated by the other welder & was treated at a local hospital as an out patient. | |||||||
Keywords:
welding, carbon dioxide, arc welding, argon
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 108406737 | Hospitalized injury | Radiation Effects | Welders and cutters |