Accident Report Detail
Accident: 133881.015 - Employee Is Killed When Steel Structure Collapses And Employ
Accident: 133881.015 -- Report ID: 0355114 -- Event Date: 02/24/2021 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
1516682.015 | 02/25/2021 | Phoenix Steel Erectors, Inc. | |||||
At 4:05 p.m. on February 24, 2021, an employee worked to connect a steel beam to adjacent columns. After connecting the beam, the employee disconnected the cran e rigging and began to walk over to the basket of an articulating lift when the structure collapsed. The employee, who was still connected to the structure with fall protection equipment, fell approximately thirty feet with the steel beam a nd column. The employee received severe head injuries that included a skull frac ture and intracranial bleeding along with an arm fracture and was killed. | |||||||
Keywords:
aerial lift, anchor, arm, basket, crane, fall, fall protection, fracture, head, rigging, skull, steel beam, steel column, steel erection, structural collapse, tie-off
| |||||||
End Use | Proj Type | Proj Cost | Stories | NonBldgHt | Fatality | ||
Commercial building | New project or new addition | X | |||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | Construction |
1 | 1516682.015 | 45 | M | Fatality | Strctural Iron /& Steel Worker | FallDist: 30 FallHt:30 Cause: Steel Erection Of Solid Web-Moving Point To Point FatCause: |