Accident Report Detail
Accident: 133336.015 - Employee Amputates Finger In Belt And Pulley
Accident: 133336.015 -- Report ID: 0950613 -- Event Date: 08/18/2020 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
1490240.015 | 08/27/2020 | Gimbal Brothers Llc | |||||
At 1:45 p.m. on September 6, 2018, an employee was working with the starch condi tioner in the tray room when he observed the NID Starch Molding machine, Plant M odel 301, being operated by a coworker, crash due to a jam. The employee jumped in to help and opened the door to the belt and pulley. The employee signaled to his coworker not to do anything, but the coworker jogged the machine while the e mployee was holding onto the belt. The employee's finger was caught between the belt and pulley. The employee was hospitalized to treat a partial amputation of his left ring finger. | |||||||
Keywords:
amputation, belt, caught between, finger, jammed, machine operator, molding machine, partial amputation, pulley
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 1490240.015 | 28 | M | Hospitalized injury | Machinery maintenance occupations |