Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 133168.015 - Employee Is Killed When Struck By Compact Track Loader

Accident: 133168.015 -- Report ID: 0523300 -- Event Date: 02/05/2021
InspectionOpen DateSICEstablishment Name
1514139.01502/06/2021Kenco Logistic Services, Llc
At 3:40 p.m. on February 5, 2021, an employee, Coworker #1 and Coworker #2 were working to clear snow from the parking lot and loading dock area of a logistics company. Coworker #1 operated a Freightliner semi-truck to move trailers while t he employee worked to connect and disconnect trailers including raising/lowering landing gear, connecting/disconnecting airlines and closing trailer doors when needed. Coworker #2 was operating a Kubota Compact Track Loader (CTL) Model SVL7 5-2 with a snowplow attachment. At the time of the incident, most of the parkin g lot was cleared except the loading dock area. The employee had connected a tra iler to Coworker #1's truck. Coworker #1 drove forward and stopped with the back of the trailer approximately 25' to 35' away from the dock. The employee walke d to the back of the trailer and was closing the trailer doors as Coworker #2 wa s driving the CTL towards the dock and in order to drag snow away from tffhe doc k. Coworker #2 struck the back of the trailer with the CTL catching the employee between the CTL and the trailer and killing him. The employee was wearing refle ctive clothing. The CTL was equipped with a flashing light and an audible backup alarm which was not functioning during the a test conducted the day after the accident.
Keywords: avulsion, back, crushed, dock, driver, fracture, loader, loading dock, material handling, motor vehicle, pinned, poor visibility, snowplow blade, struck against, struck by, tractor trailer, tractor--truck, trailer, tra
Employee # Inspection Age Sex Degree Nature
1 1514139.015 44 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.