Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 132686.015 - Employee In Crane Basket Is Pinned Against Pole And Killed

Accident: 132686.015 -- Report ID: 0653510 -- Event Date: 01/20/2021
InspectionOpen DateSICEstablishment Name
1511555.01501/21/2021Ward Electric Company, Inc.
At 11:45 a.m. on January 20, 2021, Employee #1, employed by a power line constru ction company, was working from the personnel basket of a crane and erecting a s teel transmission structure. The basket's hydraulic controls malfunctioned, cau sing the basket to pin and crush the employee against the structure. Employee # 1 was killed.
Keywords: aerial lift, basket, caught between, construction, crane, crushed, equipment failure, hydraulic crane, metal pole, personnel cage, pinned, power line worker, power trans appar, steel erection
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Powerline, transmission line New project or new addition   20 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 1511555.015 49 M Fatality Electrical and electronic equipment assemblers FallDist:
FallHt:
Cause: Erecting structural steel
FatCause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.