Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 132685.015 - Employee Is Killed While Cleaning Inside Of Restarted Mixer

Accident: 132685.015 -- Report ID: 0950612 -- Event Date: 01/23/2021
InspectionOpen DateSICEstablishment Name
1511554.01501/23/2021Kristich-Monterey Pipe Company
At 11:50 a.m. on January 23, 2021, an employee climbed into a Besser Model EM-10 0 concrete mixer to clean the machine. While the employee was inside the mixer, it restarted/cycled. The machine's safety system had been bypassed which allowe d the machine to turn on when the door to the mixer was in the open position. Th e employee was struck by the blades and interior of the mixer, killing him.
Keywords: automatic machine, blade, caught in, cleaning, concrete mixer, confined space, crushed, energized, entry permit, equipment operator, laceration, lockout, lockout/tagout, machine guarding, machine operator, mixer bla
Employee # Inspection Age Sex Degree Nature Occupation
1 1511554.015 25 M Fatality Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.