Accident Report Detail
Accident: 131478.015 - One Employee Is Killed, One Is Hospitalized When Truck Boom
Accident: 131478.015 -- Report ID: 0552700 -- Event Date: 10/16/2020 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
1499905.015 | 10/16/2020 | 102174 - Al Schultz Construction Inc | |||||
At 11:40 a.m. on October 16, 2020, Employees #1 and #2 and a coworker, employed by a poured concrete construction company, were pouring a concrete slab at a job site. The concrete pump truck, operated by the coworker, tipped toward the dri ver's side due to the failure of an outrigger base. This caused the truck boom to collapse. The boom struck Employees #1 and #2. Employee #1 was struck in th e head and killed. Employee #1, who was struck in the upper body, was transport ed to the hospital and admitted for treatment. | |||||||
Keywords:
blunt force trauma, brain, collapse, concrete pump, concrete truck, construction, equipment failure, falling object, head, lost balance, outrigger, roll-over, skull, struck by, torso, truck boom
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 1499905.015 | 34 | M | Fatality | Occupation not reported | ||
2 | 1499905.015 | 27 | M | Hospitalized injury | Occupation not reported |