Accident: 130895.015 - Employee Dies After Falling Down Unfinished Stairway

Accident: 130895.015 -- Report ID: 0454712 -- Event Date: 11/02/2020
InspectionOpen DateSICEstablishment Name
1500974.01511/03/2020Raul Antonio Herrera Leiva
At 10:45 a.m. on November 2, 2020, Employee #1 and a coworker, employed by a con struction company, were working at a new five-story multifamily residential buil ding, a multi-employer construction project. They were installing OSB (oriented strand board) engineered wood panels to the exterior of the building. Employee #1 was working inside the building on the fourth level, taking measurements and making cuts in 4 by 8 foot sheets of OSB. His coworker was outside of the buil ding in an aerial lift. Employee #1 was passing the sheets of OSB to the cowork er in the aerial lift through wall openings and over guardrails. Employee #1 re moved the top rail of a guardrail that had been installed in the doorway leading to a landing for an unfinished stairway on the fourth level of the building. T he landing had been blocked off by a mid rail and top rail to prevent access to the landing, which was approximately 5 feet wide and had an unprotected side th at measured approximately 8 feet 7.5 inches in length. As Employee #1 attempted to pick up the OSB sheet and pass it out of the window opening in the landing a rea, he lost his balance and fell backward over the unprotected side of the land ing. He fell to the basement's concrete floor below, a fall height of 42 feet 7 .5 inches. As he fell, he struck and broke diagonal 2 by 4 wood bracing that ha d been installed to keep walls plumb in the unfinished stairway. Employee #1 su stained a head injury and additional injuries to his arms and legs. Emergency m edical personnel transported Employee #1 to the hospital, where he died later th at day.
Keywords: arm, blunt force trauma, bracing, concrete, dismantling, fall, fall protection, fracture, guardrail, head, installing, leg, lost balance, material handling, multi-employer worksite, residential construction, stair la
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Multi-family dwelling New project or new addition   5 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 1500974.015 22 M Fatality Construction Laborer FallDist: 43
FallHt:43
Cause: Exterior carpentry
FatCause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.