Accident: 128765.015 - Worker Is Killed In Collapse Of Excavation Walls

Accident: 128765.015 -- Report ID: 0552651 -- Event Date: 08/19/2020
InspectionOpen DateSICEstablishment Name
1488815.01508/19/2020Debest, Incorporated
At 9:00 a.m. on August 19, 2020, an employee was working as a construction labor er for a landscaping service. He and some coworkers were working in an excavatio n. They were installing 150-millimeter (6-inch) drain line for an underground ut ilities project. The excavation had been dug by their foreman, who operated the equipment. The excavation was approximately 8.2 meters (27 feet) in length by 3. 7 meters (12 feet) in depth. The angle of repose was approximately 88 to 90 degr ees on the north, south, and east sides. Soil conditions consisted of sand mixed with clay and some gravel, with previously excavated material, consisting of va rying levels of sand and clay, mixed in at different depths. Fissures developed in the excavation walls as the depth of the excavation increased. The workers di d not immediately report the hazardous condition of the excavation walls, as non e of them recognized the hazard associated with changing soil conditions. No acc ident prevention program had been developed or coordinated with the workers. The foreman and equipment operator was working at the jobsite and was in direct and plain view of the workers exposed to the excavation collapse hazard. The near-v ertical walls collapsed onto the employee. He suffered multiple severe injuries, and he was asphyxiated by being buried under excavated materials. He was killed . At one place, the account says that he was hospitalized, so he might have died after being removed from the collapse.
Keywords: asphyxiated, buried, caught between, caught in, collapse, construction, drain pipe, equipment operator, excavation, landscaping, training, trench, unstable soil, wall
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Single family or duplex dwelling New project or new addition   X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 1488815.015 56 M Fatality Construction laborers FallDist:
FallHt:
Cause: Excavation
FatCause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.