Accident: 127179.015 - Employee Is Struck And Killed By Falling Transfer Table

Accident: 127179.015 -- Report ID: 0452110 -- Event Date: 06/17/2020
InspectionOpen DateSICEstablishment Name
1479836.01506/18/2020371162811 - Metalsa Structural Products Inc
At 12:00 a.m. on June 17, 2020, Employee # 1, a maintenance technician working o n second shift, entered a welding cell to perform maintenance on the cylinder th at lifts the transfer table. The transfer table was in the elevated position. He replaced one solenoid and it did not fix the problem. Employee # 1 started to replace a second one, and the transfer table fell down on him. He was killed.
Keywords: crushed, cylinder, falling object, struck by, welding
Employee # Inspection Age Sex Degree Nature Occupation
1 1479836.015 58 M Fatality Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.