Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Alert: Due to routine maintenance on the OSHA website, some pages may be temporarily unavailable.
To report an emergency, file a complaint with OSHA or ask a safety and health question, call 1-800-321-6742 (OSHA).

Accident Report Detail

Accident: 126568.015 - Employee Is Killed After Being Run Over By Coworker

Accident: 126568.015 -- Report ID: 0418800 -- Event Date: 05/28/2020
InspectionOpen DateSICEstablishment Name
1476969.01505/29/2020U.S. Sugar Corp.
At 4:45 p.m. on May 28, 2020, Employee # 1 arrived at work and was struck by ano ther employee's vehicle at parking lot. He was killed.
Keywords: driver, motor vehicle, run over, struck by, vehicle
Employee # Inspection Age Sex Degree Nature
1 1476969.015 57 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close