Accident: 121752.015 - Employee Dies In Explosive Reaction
Accident: 121752.015 -- Report ID: 0111400 -- Event Date: 11/05/2019 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
1445321.015 | 11/15/2019 | Cannan Group Inc | |||||
At 12:00 p.m. on November 5, 2019, Employee #1 was making a small spot weld on a piece of metal. He was performing the weld on a drum of that contained flammabl e windshield washer fluid. There was an explosive reaction, and the cover of dru m hit the employee's face. Liquid splashed on the employee and was ignited by th e explosion. Employee #1's clothes caught on fire. He sustained body burns and w as killed. | |||||||
Keywords:
burn, drum, explosion, fire, flammable liquid, welding
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 1445321.015 | 64 | M | Fatality | Machinery maintenance occupations |