Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 121529.015 - Employee Is Killed When Incompatible Cleaning Chemicals Are

Accident: 121529.015 -- Report ID: 0134000 -- Event Date: 11/07/2019
InspectionOpen DateSICEstablishment Name
1443690.01511/08/2019Jk & T Wings, Inc.
At approximately 5:00 p.m. on November 7, 2019, an employee was working at a ful l-service restaurant. He was working as the general manager, and he was overseei ng the operation of the restaurant. At least two coworkers were present at the t ime of the incident. The first coworker was a cook. The employee was working wit h the cook to clean and organize the back hallway of the restaurant. The second worker present was the assistant general manager. The employee would be transfer ring control of the restaurant to the assistant general manager soon. Employee # 1 left the cook to clean the area. The assistant general manager arrived to star t working shortly after the employee left the area. The assistant general manage r had a brief conversation with the cook. Shortly after that, the cook poured a gallon of Super 8, a sodium hypochlorite-based disinfectant, all over the floor of the back hallway. The cook then left the area. When he returned, he poured a gallon of Scale Kleen, an acid-based scale remover, all over the back hallway. T he second liquid combined with the Super 8. The cook then began to scrub the flo or with a long-handled brush. The combination of these cleaning chemicals result ed in the creation of a toxic atmosphere. The fumes were irritating to the respi ratory tract, eyes, and skin of the people in the immediate and surrounding area . The cook notified the assistant general manager of the problem. The assistant general manager attempted to clear the mixture out of the back door of the resta urant. The cook had propped the door open. The employee took over the effort of squeegeeing the combination of cleaning chemicals out of the back door. He was s oon overcome by the fumes. He sustained a seizure from which he did not recover. Following his noticeable debilitation, the coworkers contacted emergency servic es. They took over control of the scene when they arrived. The employee was take n to a hospital. The employee was declared dead at the hospital. Meanwhile, betw een the time emergency services had been contacted and their arrival, the cook c ontinued to squeegee the combination of cleaning chemicals out the back door. He also went through the danger area to the kitchen to remove some food from the f ryer. He was one of many of the restaurant workers who initially evacuated throu gh the danger area. Several of these workers also returned to the danger prior t o any evidence that the hazardous atmosphere had subsided. Only the employee, th e cook, and the assistant general manager were involved directly in the response to the incident. The employee died as the result of this incident. His employer believed that a pre-existing medical condition contributed to his severe reacti on. Numerous other workers sustained varying degrees of irritation to their resp iratory tracts, eyes, and skin. Eight workers were admitted to the hospital for observation and testing and released shortly thereafter. According to reports by the Burlington MA police and fire departments, six other individuals were also admitted to the hospital for the same reason. The toxic atmosphere created by th e combination of the Super 8 and the Scale Kleen was the cause of the harm.
Keywords: chemical reaction, chemical vapor, cleaning, eye, inhalation, lung, poisoning, respiratory tract, restaurant, skin, toxic atmosphere, vapor
Employee # Inspection Age Sex Degree Nature Occupation
1 1443690.015 32 M Fatality Managers and administrators, n.e.c

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close