Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 120672.015 - Employee Fractures, Cuts Fingers When Caught In Conveyor Pul

Accident: 120672.015 -- Report ID: 0950625 -- Event Date: 05/29/2019
InspectionOpen DateSICEstablishment Name
1410976.01506/25/2019Randstad Us, Llc
At 11:15 a.m. on May 29, 2019, an employee was working the sealer position on a citrus line verifying lids on fruit boxes coming through the taping machine were closing and taped properly. The employee walked over to the full box conveyor l ine about 10 feet behind his work station when he caught his left hand in the id ler pulley. The employee fractured and lacerated his fingers and was hospitalize d.
Keywords: caught between, conveyor, crushed, finger, food processing, fracture, guard, hand, idler, inexperience, laceration, machine guarding, material handling, ppe, pinched, pulley, puncture, sealing machine, staffing agency,
Employee # Inspection Age Sex Degree Nature Occupation
1 1410976.015 33 M Hospitalized injury Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close