Accident Report Detail

Accident: 120464.015 - Employee Is Killed When Struck By Gate Arm Wheel Of Pile Dri

Accident: 120464.015 -- Report ID: 0625700 -- Event Date: 10/03/2019
InspectionOpen DateSICEstablishment Name
1435952.01510/04/2019Cayo, Llc
At 11:38 a.m. on October 3, 2019, Employee #1 was using a pile driver (heavy equ ipment) to perform an earthwork construction operation. Employee #1 moved the h ydraulic lines, at the base of the pile driving leads, so they were free to move up and down with the hammer. Afterwards, a wheel from the hydraulic gate arm, assembly approximately 70 feet up the 2:1 leads, came off the bolt and needle be aring assembly and struck Employee #1 in the head. Employee #1 then sustained h ead trauma and was killed.
Keywords: accidental discharge, arm, bearing, blunt force, blunt force trauma, bolt, construction, construction vehicle, earthmoving equip, head, hydraulic cylinder, hydraulic line, lost consciousness, pile driver, struck by
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Other heavy construction Alteration or rehabilitation   X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 1435952.015 32 M Fatality Pile-Driver Operator FallDist:
FallHt:
Cause: Pile driving
FatCause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.