Accident: 119059.015 - Employee Is Ejected From Utility Vehicle And Killed

Accident: 119059.015 -- Report ID: 1032100 -- Event Date: 08/18/2019
InspectionOpen DateSICEstablishment Name
1424292.01508/19/2019Air Force
At 11:00 or 11:30 a.m. on August 18, 2019, an employee was working for the Unite s States Air Force. He was operating a utility vehicle or all-terrain vehicle (A TV) along a designated golf course pathway. He was using the ATV to move through out the golf course as he marshaled a "best ball" golf tournament. The ATV was P olaris Ranger 6 x 6 utility vehicle, with Model Number 204562 and Serial Number 4XARF68A694737528. The pathway surface was approximately three meters (ten feet) wide. It was essentially level, sloping three degrees to the left in the direct ion of travel. It was paved with a smooth asphalt finish. Weather conditions wer e sunny and clear, with strong winds and strong gusts predominantly out of a nor th to northeast direction. The employee was traveling in a south to southeast di rection from the clubhouse area, via the eastern edge of the driving range parki ng lot to the approach pathway. He was traveling from the clubhouse area to the tenth hole of the course. Along the way, he approached gate 10. It was made of 5 0-millimeter (2-inch) steel tubing. The gate had been opened at 4:00 a.m. that m orning. At some point during the morning, the gate had become free from its bolt and chain assembly. It could swing freely across the pathway. At approximately 11:30 a.m. the vehicle struck the gate. The employee was ejected from the ATV to the left side of the pathway, approximately 4.3 meters (14 feet) from the left hand gate post. He was not wearing a seat belt. This area is made up of large bo ulders and vegetation that includes grass and some small shrubs. The employee wa s found unresponsive by a coworker. The employee was found facing upward, with h is feet oriented in a southwest direction. Life saving measures were attempted a nd emergency response was summoned. The employee had sustained severe trauma to his lower body cavity. He was killed.
Keywords: atv, ejected, emergency response, fence, riding on equipment, struck against
Employee # Inspection Age Sex Degree Nature Occupation
1 1424292.015 39 M Fatality Managers and administrators, n.e.c

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close