Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 118881.015 - Employee Is Killed When Struck By Rope Under Tension

Accident: 118881.015 -- Report ID: 0626700 -- Event Date: 08/08/2019
InspectionOpen DateSICEstablishment Name
1422643.01508/09/2019Traf-Tex Inc.
At 2:42 p.m. on August 8, 2019, Employee #1, employed by a traffic control syste ms company, was working at a heavy construction project. As a backhoe pulled ro pe and conduit from an underground pull box, he used a small traffic sign to red irect the path of the rope. He was monitoring the tension on the rope when the traffic sign bent in half. The rope struck Employee #1 and pushed him into a tr uck. He sustained blunt force trauma injuries to the head and was killed.
Keywords: backhoe, brain, caught between, conduit, construction, head, rope, struck against, struck by, traffic control, truck
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Other heavy construction New project or new addition   X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 1422643.015 49 M Fatality Supervisors; plumbers, pipefitters & steamfitters FallDist:
FallHt:
Cause: Other Activities-Installing Ornamental And Archite
FatCause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.