Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 117544.015 - Employee Is Killed By Exploding Semi-Trailer Tire

Accident: 117544.015 -- Report ID: 0751910 -- Event Date: 06/27/2019
InspectionOpen DateSICEstablishment Name
1412122.01506/28/2019Lone Star Truck And Tire Inc
At 3:07 p.m. on June 27, 2019, an employee plugged and patched a steel radial tu beless semi-trailer tire and mounted it on a steel wheel. The employee sprayed s tarting fluid inside the tire and ignited it with a propane torch. The explosion seated the bead and the employee inflated the tire to approximately 100 psi. Th e employee placed the outside tire and aluminum wheel assembly on the axle and h and threaded 10 lug nuts one or two turns onto the studs. The employee retrieved an air impact wrench and bent over in front of the wheel to begin tightening th e lug nuts. There was bead failure on the inside dual causing a sudden release o f air that forced the outside wheel to strike the employee in the head and chest area. The hand tightened lug nuts were forced off and the employee was knocked backwards approximately 13 feet and was killed when the employee struck the righ t rear area of another semi-trailer that was backed in the next stall.
Keywords: chest, head, single piece rim, struck against, struck by, tire, tractor trailer, wheel
Employee # Inspection Age Sex Degree Nature
1 1412122.015 35 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close