Accident Report Detail
Accident: 116887.015 - Employee Is Paralyzed From Fall Through Skylight
Accident: 116887.015 -- Report ID: 0950641 -- Event Date: 04/19/2019 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
1399563.015 | 05/09/2019 | Ericsson, Inc. / Eus, Inc. | |||||
At 11:20 a.m. on April 19, 2019, an employee was clearing an antenna to perform troubleshooting to radio frequency equipment on the roof of a commercial buildin g. The employee leaned over a skylight on the north side of the roof and when he put his weight on the skylight he fell through. The employee was hospitalized a nd was paralyzed from the waist down. | |||||||
Keywords:
antenna, blunt force, blunt force trauma, building, fall, fall protection, maintenance, nerve damage, paralysis, repair, roof, roof opening, skylight, spine, telecom work, torso, unstable position, unstable surface
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 1399563.015 | 22 | M | Hospitalized injury | Technicians, n.e.c. |