Accident Report Detail
Accident: 116754.015 - Employee Breaks Leg And Ribs When Struck By Felled Tree
Accident: 116754.015 -- Report ID: 0950615 -- Event Date: 05/28/2019 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
1405090.015 | 06/03/2019 | Sandborn Tree Service | |||||
At 2:20 p.m. on May 28, 2019, an employee was removing two leaders that had alre ady been topped by a coworker from an amber tree. The employee had put a face cu t in the tree, and then put a back cut all way through the face cut leaving the tree unstable. The employee walked into the falling path of the tree and it fell and struck him knocking him to the ground. The employee suffered a broken left femur and ten broken ribs, requiring hospitalization. | |||||||
Keywords:
back cut, blunt force, blunt force trauma, chest, falling object, leg, rib, struck by, topping, training, tree, tree felling, tree limb, tree section
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 1405090.015 | 43 | M | Hospitalized injury | Laborers, except construction |