Accident: 116239.015 - Employee Hits Propane Line With Walk-Behind Trencher And Is

Accident: 116239.015 -- Report ID: 0950624 -- Event Date: 12/20/2018
InspectionOpen DateSICEstablishment Name
1368257.01512/24/2018O.C. Communications, Inc
At 9:13 a.m. on December 20, 2018, an employee used a walk-behind trencher (Barr eto Model # 712MT) to prepare for a cable line installation. At some point, the trencher struck an underground propane pipe, which exploded and continued to bur n. The employee was burned in the explosion and taken to a local hospital to tre at second-degree burns to the face and neck.
Keywords: burn, communication cable, explosion, face, installing, neck, pipe, pipeline, propane, struck against, trench
Employee # Inspection Age Sex Degree Nature
1 1368257.015 19 M Non Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.