Accident Report Detail
Accident: 115777.015 - Employee Is Burned Following Furnace Explosion
Accident: 115777.015 -- Report ID: 1054191 -- Event Date: 01/07/2019 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
1392871.015 | 01/09/2019 | 3325 | 317723023 - Esco Group Llc | ||||
At 10:00 p.m. on January 7, 2019, an employee was working near a furnace when he was hit in the left knee by super heated oxygen. An explosion occurred in the f urnace due to a malfunctioning oxygen lance causing the release. The employee's FR clothing failed allowing the hot material to contact and burn his knee, resul ting in him being hospitalized. | |||||||
Keywords:
burn, clothing, fire, furnace, high temperature, inadequate maint, knee, maintenance, malfunction, mech malfunction, melting furnace, molten metal, oxygen, ppe, protective clothing, steel-melting furn, temperature, tr
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | Construction |
1 | 1392871.015 | 33 | M | Hospitalized injury | Misc. metal & plastic processing machine operators | FallDist: FallHt: Cause: Other Activities-Installing Ornamental And Archite FatCause: |