Accident: 115448.015 - Employee Adjusting Machinery Sustains Finger Amputation

Accident: 115448.015 -- Report ID: 0521100 -- Event Date: 04/09/2019
InspectionOpen DateSICEstablishment Name
1393788.01504/17/2019Kdc One Northern Labs
At 4:00 p.m. on April 9, 2019, an employee was working for a firm that manufactu red and packaged, under contract, liquid products for such personal care categor ies as deodorants, bath and body, and skin care. It was a consumer and automotiv e packaging company that specialized in the packaging of liquids and gels. The c ompany operated a multitude of automated product lines and machinery that requir ed adjustments and maintenance. In order for employees to conduct these operatio ns, specific lockout/tagout procedures had been developed to ensure that there w as no potential for accidental start up when employees were exposed to the hazar dous operations of the machines. The employee was working as a line technician. He was responsible for machine setup and adjustments to the machines for anythin g short of repair. He was completing a common task for line technicians: manuall y adjusting the torque wheels of the capper section of line Number 3. He had ope ned up the guard doors to the capper section and was making adjustments as the m achine ran. While making the adjustments, he noticed that a bottle had fallen. H e reached over to upright the bottle. As he did this, his fingers were caught in the chain and sprocket of the machine's rear drive chain. Three of his fingers were caught in the chain and sprocket. The location of the nip point was 0.64 me ters (25 inches) from the opening of the guard. There was also a nearer chain, l ocated 0.23 meters (9 inches) from the opening. He suffered either a partial or complete amputation of the small finger and severe lacerations of the ring and m iddle fingers, all on his right hand. He was hospitalized. At the time of the in cident, the specific procedure did not account for the pneumatic energy source o f the machine and only advised the isolation of the electrical energy source.
Keywords: amputated, amputation, caught between, caught in, chain, finger, laceration, lockout, lockout/tagout, maintenance, partial amputation, sprocket, work rules
Employee # Inspection Age Sex Degree Nature Occupation
1 1393788.015 27 M Hospitalized injury Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close