Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 115184.015 - Employee Falls And Incurs Multiple Injuries

Accident: 115184.015 -- Report ID: 0950613 -- Event Date: 01/30/2019
InspectionOpen DateSICEstablishment Name
1377649.01502/11/2019J. Mitchell Construction Inc.
At approximately 4:15 p.m. on January 30, 2019, Employee #1 was framing a struct ure when he fell approximately 13 feet to the ground below. Employee #1 suffered a fractured elbow, ankle, and ribs, and was hospitalized.
Keywords: ankle, elbow, fall, framing, rib
Employee # Inspection Age Sex Degree Nature Occupation
1 1377649.015 34 M Hospitalized injury Carpenters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close