Accident: 115108.015 - Three Employees Are Struck By Elevated Metal Skirt During Fa

Accident: 115108.015 -- Report ID: 0626600 -- Event Date: 04/04/2019
InspectionOpen DateSICEstablishment Name
1391019.01504/05/2019Spitzer Industries, Inc.
At 9:00 p.m. on April 4, 2019, three employees were mating a base skirt section weighing 21, 559 lbs to the main part of a pressure vessel. Employee #1 and Employee #3 were taking measurements of the skirt while it was elevated by slings approximately 4 feet above the floor when the gravity center shifted and the skirt fell from the slings, striking Employee #1 and Employee #3. Employee #2 was pushed away by Employee #1 and fell to the ground. Employee #1 had his left arm and leg severed as well as sustaining blunt force trauma to his torso and died enroute to the hospital. Employee #3 was pronounced dead at the scene. Employee #2 sustained minor scrape and bruises; however, he did not need hospitalization.
Keywords: struck by, amputated, arm, crushed, amputation, leg, torso
Employee # Inspection Age Sex Degree Nature Occupation
1 1391019.015 30 M Fatality Other Welders and cutters
2 1391019.015 28 M Fatality Other
3 1391019.015 34 M Non Hospitalized injury Bruise/Contus/Abras Crane Operator

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close